Hitachi UPS System

The UPS system is the most important device to be installed to protect costly equipment from high voltage, Short circuits, and dangerous electrical threats. In India due to fast development every manufacturer, Institute, Industries, and hospital prefer to install an Online UPS system nowadays. We Powertune understands this need of the industry and propose the best UPS Brand to our customers always. Hitachi UPS system is One of the best UPS Systems in India and we are dealers of Hitachi UPS system in the thane, Navi Mumbai, Badlapur, Dombivli, Kalyan, Ambernath MIDC, Ambernath, Taloja MIDC, and Mhape MIDC areas.

About Hitachi UPS System Brand :

Established and laid out in 1983 as Hi-Rel Electronics Pvt. Ltd., which later on in the year 2015 had turned into the 100 percent auxiliary organization of Hitachi, Japan which is one of the Global fortune 500 organizations with another name as Hitachi Hi-Rel Power Electronics Private Limited, which is being perceived as one of the trailblazers in the influence hardware space. Hitachi Hi-Rel, today, is the main producer of Industrial UPS, IT and Infra UPS, Medium and Low Voltage Variable Frequency Drives, Grid Tied Solar Inverters, Air Compressors, and Railway Inverters.

Hitachi Hi-Rel has a cutting-edge manufacturing facility at Sanand close to Ahmedabad in Gujarat-India. Hitachi Hi-Rel is helping a wide exhibit of ventures and associations to fulfill the crucial needs through mechanically predominant, low dirtying, and creative items Solutions and keep on offering elite power hardware items, esteem added administrations and modified arrangements
Read more

What is the UPS system? How its work?

UPS ( uninterruptible power supply) systems do two things, one is to give power back up to the equipment and the other is to save from the crisis coming from the power line. A battery bank is attached to the UPS through which it gives electric power when there is no electricity. It also constantly changes the form of electricity coming from the grid, creates a new form, and sends it to the equipment through which the equipment gets controlled and safe electric power and remains protected. Which is called dual conversion in technical language. So the conclusion is installing UPS System is necessary and important to the life of the equipment.

Read my separate article on What is an Online UPS system? why it’s important?

Hitachi UPS system models

UPS system is a project base solution so its specification is based on the needs of the customer and the project input given by him. Although Hitachi is basically a project-based company it is difficult to explore all the models in a standard format. But if you want more information about it, you can contact us by clicking here.

Three basic types of UPS system

  1. Single Phase UPS System
  2. Three Phase in one phase out UPS System
  3. Three Phase in Three Phase Out UPS System

Some basic Hitachi UPS System Models

1. Single Phase UPS System.

Features :

  1. Input reactors to minimize AC mains notching
  2. High branch fast-acting fuse clearing capacity (up to 30% rated fuse) feedback handles nonlinear loads up to Crest Factor 3:1 with <5% THD
  3. Sinusoidal PWM operation with direct AC operation —
  4. Specially designed output transformer for PWM
  5. High efficiency: IGBT-based inverter — Automatic Battery Charging Float / Boost mode selection with current limit
  6. DSP-based control Redundant control power supplies Programmable static switch with up to ±6%synchronization window Comprehensive LED mimic and LCD + keypad enabled Date Time stamped event recording 999 events logged in non-volatile memory Programming & Monitoring of various system parameters.
  7. RS485 interface and programmable potential free contacts
  8. 050 C Ambient in IP 41 Enclosure
  9. Front access-oriented layout PC-based Monitoring, Control & Reporting unit (Optional)Monitors the system performance with automatic generation of daily weekly reports
    with fault and alarm log details.
  10. Higher level connectivity with DCS/PLC through RTU for Modbus TCP/IP. Monitoring on LAN through SNMP Battery Monitoring System.
Technical Specification
MAINS INPUT 
Voltage415 V +10% – 15% 3Ph 3W
Frequency50 Hz ±10%
DC BUS 
DC Voltage Range305V to 482V
Maximum DC Bus Ripple (without battery)2% RMS
Max DC Bus Ripple (with battery)1% RMS
OUTPUT 
Nominal AC Voltage110/115/120/220/230/240 V
Load Power Factor – Rated0.8
Load Power Factor – Range0.6 to Unity
Voltage Regulation 
Steady State±1%
100% Step Load±5% typical
Recovery Time to 98%< 20 ms
Over Load 
110%3600 Seconds
125%600 Seconds
150%60 seconds
Branch Fuse Clearing Ability30% of UPS rated current (fast acting semiconductor protection fuse)10% of UPS rated current (slow acting fuse))
Frequency50 Hz
Bypass Synchronization Window±1% to 6% (Field Programmable)
Internal Oscillator±0.1%
Slew Rate1 Hz/Sec
Total Harmonic Distortion 
Linear Load<2.5%
Nonlinear Load (CF 3:1)<5%
OPERATING CONDITIONS 
Ambient Temperature500C
Altitude1000 Meter From MSL
Humidity95% Non-Condensing
AtmosphereNon Corrosive, Dust Free, Freely Ventilated
Audible Noise @ 1metre from Panel Front55 dBA to 75 dBA (depending on system rating and Configuration)
ENCLOSURES 
ConstructionCRCA Steel Sheet
Protection Class 
Finish (Powder Coated)RAL 7032 (Other Colours Optional)
VentilationForced Air (Internal Fans)
Cable EntryBottom (Top Optional)
Role of Powertune in presenting and installing UPS Systems

We Powertune are fully responsible for ensuring that the ups system we have suggested to you will meet your requirements. We are a network-based organization and we work as a team with industry experts. We survey the site in a pre-planned manner and give you the right and correct solution. currently, we are operating in thane, Navi Mumbai, Badlapur, Dombivli, Kalyan, and Ambernath.

For a free site, survey feel your basic details to get the call

wpChatIcon
    wpChatIcon
    Call now