Swastik Online UPS is the most trusted online UPS in Mumbai and the sub-cities of Mumbai. Swastik has a manufacturing plant at bhivandi it’s an almost 25 years+ old company. Swastik developed its own technology with some unique benefits. We Powertune proudly sell Swastik online UPS as we got a great result at our selling experience. We have authorized Swastik online ups in the thane, badlapur, Dombivli, Kalyan, Ambernath MIDC, Ambernath, Taloja MIDC, and Mhape MIDC area.
Swastik Online UPS dealers
We Powertune are a network-based organization typed with experts at multiple locations with the intention to provide the best-in-class service at a reasonable value. We are authorized dealers on Swastik online UPS. We Take care of customer needs and satisfaction while proposing solutions. we follow well-written proven steps to complete the project successfully. We do a site survey, discuss the customer for his final expectation, understand his need, and suggest the right solution.
Learn more about What is an Online UPS system? why it’s important?
Swastik Online UPS
1. Single Phase Online UPS ( 1 Phase in 1 Phase out )
This Online UPS is extremely useful for offices, labs to run computers alongside printers and few lights just in case of an influence outage for an extended time. The output of this Online UPS is regulated pure wave with low noise using high power IGBT modules.
This Online UPS can run Desktop computers, matrix printers, laser printers, flex printing machines, and machines utilized in laboratories. With an LCD display you’ll read input, output voltage also as output and battery charging current.
Programming is provided to pick power battery type, battery charging current, and inverter on warning.
Silent Features :
- Pure Sine Wave Output | Best for sensitive type of load
- High-Frequency PWM create Low Noise
- True Double Conversion | True Online UPS reborn Sine wave output
- With Galvanic Isolation at Output using Transformer | Sturdy and less failure.
- LCD Display to Read
- Input, Output, and Battery Voltage
- Output and Battery Charging Current
- Capable of High Peak Load Currents | work smoothly with induction, compressor, and motor type of load
- Rugged SCR Charger | Less failure long working life
- High-Quality Connectors
- Short Circuit Protection for IGBT | Can handle worst power condition without fail
- Over Temperature Protection | Work in multiple environmental conditions
- Can Charge Big Tubular Batteries | great for long back up need.
- Manual Bypass Switch as Standard | Can anyone bypass the system at unexpected system failure.
Technical Specification :
Type | One Phase In One Phase Out Online UPS | |
Model | 3 KVA – 10 KVA | |
Input AC | Voltage range | 190 V – 270 V AC |
Frequency | 48 – 52 Hz | |
PF | 0.7 – 0.8 | |
Battery | Voltage | 72 V – 192V |
Charging Current | 4 – 10 Amps | |
Type | SMF / Tubular | |
Boost Cut-off Voltage | 13.8 V for SMF Battery / 14.4 V for Tubular Battery | |
Battery Low trip early warning | 10.8 Volts | |
Battery low trip | 10 V | |
Output | Waveform | Pure Sine wave |
THD | 3 % for linear load / 5 % for Non linear load | |
Crest Factor | 1:03 | |
Frequency | 50 Hz +/- 0.5 Hz | |
Voltage | 230 V AC +/- 2% | |
PF | 0.8 lagging | |
Galvanic Isolation | With Isolation Transformer | |
Inverter | Technology | Center Align HF PWM |
Switching Device | IGBT Modules | |
Galvanic Isolation | With Isolation Transformer | |
Charger | Technology | Phase Control |
Switching Device | Thyristor Modules | |
Protections | Input | MCB |
Output | Electronic trip for overload and short circuit | |
Battery reverse polarity | Fuse link / HRC fuse | |
Indications | LCD | Input, Output and Battery Voltage |
Output and Battery Charging Current | ||
LEDs | Mains OK, Inverter On, Overload, Charging On | |
Battery Low, System On & off | ||
Audio | Batter low trip early warning | |
Overload trip early warning | ||
Mains fail warning | ||
Bypass Switch | Manual | Electro mechanical |
Humidity |
2. Three Phase Online UPS ( 3 Phase in 1 Phase out )
This Online UPS is extremely useful for offices, labs to run computers alongside printers and few lights just in case of an influence outage for an extended time. The output of this Online UPS is regulated pure wave with low noise using high power IGBT modules.
This Online UPS can run Desktop computers, matrix printers, laser printers, flex printing machines, and machines utilized in laboratories. With LCD display you’ll read input, output voltage also as output and battery charging current.
Programming is provided to pick power battery type, battery charging current, and inverter on warning.
Features :
- Pure Sine Wave Output | Best for sensitive type of load
- High-Frequency PWM create Low Noise
- True Double Conversion | True Online UPS reborn Sine wave output
- With Galvanic Isolation at Output using Transformer | Sturdy and less failure.
- LCD Display to Read
- Input, Output, and Battery Voltage
- Output and Battery Charging Current
- Capable of High Peak Load Currents | work smoothly with induction, compressor, and motor type of load
- Rugged SCR Charger | Less failure long working life
- High-Quality Connectors
- Short Circuit Protection for IGBT | Can handle worst power condition without fail
- Over Temperature Protection | Work in multiple environmental conditions
- Can Charge Big Tubular Batteries | great for long back up need.
- Manual Bypass Switch as Standard | Can anyone bypass the system at unexpected system failure.
Technical Specification :
Type | Three Phase In One Phase Out Online UPS | |
Model | 6 KVA – 25 KVA | |
Input AC | Voltage range | 415 V +/- 5 % |
Type | 3 Phase 4 Wires | |
Frequency | 48 – 52 Hz | |
PF | 0.8 – 0.9 | |
Battery | Voltage | 144 V – 360V |
Charging Current | 4 – 10 Amps | |
Type | SMF / Tubular | |
Boost Cut-off Voltage | 13.8 V for SMF Battery / 14.4 V for Tubular Battery | |
Battery Low ea trip early warning | 10.8 Volts | |
Battery low trip | 10 V | |
Output | Waveform | Pure Sine wave |
THD | 3 % for linear load / 5 % for Non linear load | |
Crest Factor | 1:03 | |
Frequency | 50 Hz +/- 0.5 Hz | |
Voltage | 230 V AC +/- 2% | |
PF | 0.8 lagging | |
Galvanic Isolation | With Isolation Transformer | |
Inverter | Technology | Center Align HF PWM |
Switching Device | IGBT Modules | |
Galvanic Isolation | With Isolation Transformer | |
Charger | Technology | Phase Control |
Switching Device | Thyristor Modules | |
Protections | Input | MCB |
Output | Electronic trip for overload and short circuit | |
Battery reverse polarity | Fuse link / HRC fuse | |
Indications | LCD | Input, Output and Battery Voltage |
Output and Battery Charging Current | ||
LEDs | Mains OK, Inverter On, Overload, Charging On | |
Battery Low, System On | ||
Audio | Batter low trip early warning | |
Overload trip early warning | ||
Mains fail warning | ||
Bypass Switch | Manual | Electromechanical |
3. Three Phase Online UPS ( 3 Phase in 3 Phase out )
This Online UPS is extremely helpful for little engineering workshops and offices. It provides clean, regulated, Isolated power.
It is often used for brief or while backups just in case of equipment failure. The output of this Online UPS is regulated pure sine wave output with low noise using high-power IGBT modules.
This Online UPS will run Desktop computers, printing machines, CNC machines, and elevators.
Silent features
- Pure Sine Wave Output | Best for sensitive type of load
- High-Frequency PWM create Low Noise
- True Double Conversion | True Online UPS reborn Sine wave output
- With Galvanic Isolation at Output using Transformer | Sturdy and less failure.
- LCD Display to Read
- Input, Output, and Battery Voltage
- Output and Battery Charging Current
- Capable of High Peak Load Currents | work smoothly with induction, compressor, and motor type of load
- Rugged SCR Charger | Less failure long working life
- High-Quality Connectors
- Short Circuit Protection for IGBT | Can handle worst power condition without fail
- Over Temperature Protection | Work in multiple environmental conditions
- Can Charge Big Tubular Batteries | great for long back up need.
- Manual Bypass Switch as Standard | Can anyone bypass the system at unexpected system failure.
Technical Specification
Type | Three Phase In Three Phase Out Balance Online UPS | |
Model | 8 KVA – 30 KVA | |
Input AC | Voltage range | 415 V +/- 5 % |
Type | 3 Phase 4 Wires | |
Frequency | 48 – 52 Hz | |
PF | 0.8- 0.9 | |
Battery | Voltage | 180 V – 360V |
Charging Current | 4 – 10 Amps | |
Type | SMF / Tubular | |
Boost Cut-off Voltage | 13.8 V for SMF Battery / 14.4 V for Tubular Battery | |
Battery Low trip early warning | 10.8 Volts | |
Battery low trip | 10 V | |
Output | Waveform | Pure Sine wave |
THD | 3 % for linear load / 5 % for Non linear load | |
Crest Factor | 1:03 | |
Frequency | 50 Hz +/- 0.5 Hz | |
Voltage | 230 /240 V AC +/- 2 % phase to neutral / 400/ 415 V AC phase to phase | |
Load Unbalance | 25 % maximum | |
PF | 0.8 lagging | |
Galvanic Isolation | With Isolation Transformer | |
Inverter | Technology | Center Align HF PWM |
Switching Device | IGBT Modules | |
Galvanic Isolation | With Isolation Transformer | |
Charger | Technology | 6 Pulse Converter |
Switching Device | Thyristor Modules | |
Protections | Input | MCB |
Output | Electronic trip for overload and short circuit | |
Battery reverse polarity | Fuse link / HRC fuse | |
Indications | LCD | Input, Output and Battery Voltage |
Output and Battery Charging Current | ||
LEDs | Mains OK, Inverter On, Overload, Charging On | |
Battery Low, System On | ||
Audio | Batter low trip early warning | |
Overload trip early warning | ||
Mains fail warning | ||
Bypass Switch | Manual | Electro mechanical |
Above all Swastik online UPS are used for commercial purposes, Online ups are suitable is based on customer need analyses. for more fill in your few details to get a call back from an expert.
Area of operation :